Technical data
Technical data – electrical ratings
- Voltage supply
-
- 9…30 VDC
- 5 VDC ±5 %
- Consumption w/o load
-
- ≤100 mA
- Pulses per revolution
-
- 300 … 5000
- Phase shift
-
- 90 ° ±20°
- Scan ratio
-
- 40…60 %
- Reference signal
-
- Zero pulse, width 90°
- Sensing method
-
- Optical
- Output frequency
-
- ≤120 kHz
- ≤300 kHz (on request)
- Output signals
-
- K1, K2, K0 + inverted
- Error output (only EMS)
- Output stages
-
- HTL-P (power linedriver)
- TTL/RS422
- Shaft insulation
-
- 2,8 kV
- Transmission length
-
- ≤350 m at 100 kHz (HTL-P)
- ≤550 m at 100 kHz (TTL)
- Interference immunity
-
- EN 61000-6-2
- Emitted interference
-
- EN 61000-6-3
- Approval
-
- CE
- UL approval / E256710
Technical data – mechanical design
- Size (flange)
-
- ø105 mm
- Shaft type
-
- ø12…20 mm (blind hollow shaft)
- ø17 mm (cone shaft 1:10)
- Admitted shaft load
-
- ≤450 N axial
- ≤600 N radial
- Protection DIN EN 60529
-
- IP 66
- Operating speed
-
- ≤6000 rpm (mechanical)
- Operating torque typ.
-
- 6 Ncm
- Rotor moment of inertia
-
- 340 gcm²
- Material
-
- Housing: aluminium die-cast
- Shaft: stainless steel
- Operating temperature
-
- -40…+100 °C
- -25…+100 °C (>3072 pulses per revolution)
- -50…+100 °C (optional)
- Resistance
-
- IEC 60068-2-6 Vibration 20 g, 10-2000 Hz
- IEC 60068-2-27 Shock 300 g, 6 ms
- Corrosion protection
-
- IEC 60068-2-52 Salt mist
- Complies to ISO 12944-5:1998 Protective paint systems (C4)
- Explosion protection
-
- II 3 G Ex nA IIC T4 Gc (gas)
- II 3 D Ex tc IIIC T135°C Dc (dust)
- Connection
-
- Terminal box
- Terminal cover
- 2x terminal box (with option M)
- Weight approx.
-
- 1,6 kg
- 1,8 kg (with option M)